dc.description.abstract |
The dynamic stiffness properties of soils must be determined for the purpose of
analyzing machine foundations and substructures subjected to earthquakes. The
significant advances in mathematical techniques for analyzing dynamic soil-structure
interaction problems necessitate a realistic determination of pertinent stiffness
properties. This determination can be quite involved because of the dependence of
these properties on a large number of parameters. During the past three decades,
reinforced earth has been extensively used to improve the static strength
characteristics of soils. The study of dynamic response of foundations on reinforced
sand beds and the dynamic properties, however, has not received the needed quantum of
attention.
The present research work has been carried out to study the dynamic response of
foundations on reinforced sand beds experimentally and to interpret the dynamic
stiffness properties of reinforced sand on the basis of experimental data and
analytical analysis. It is anticipated that the study would help in better
understanding of the dynamic behaviour of foundations on reinforced sand beds and
lead to realistic and safe design.
In India, the cyclic plate load and block vibration tests are generally used for
the determination of dynamic stiffness properties of soils. A large number of
reinforcement parameters are likely to influence the dynamic behaviour of soil; the
present study, however, has been undertaken to investigate the following aspects :
(1) The effect of size & number of reinforcement layers, density of sand and size of
footing on the coefficient of elastic uniform compression, Cu of the sand by
performing cyclic plate load tests in the laboratory.
(2) To perform vertical and horizontal forced vibration tests on reinforced sand
beds in the laboratory to study the effect of size and number of reinforcement
layers on the dynamic response, coefficient of elastic uniform compression Cu,
the coefficient of elastic uniform shear CT and the damping ratio.
(3) Analysis and interpretation of experimental data for developing non-dimensional
plots and correlations.
(4) To develop an analytical approach for determining the coefficient of elastic
uniform compression Cu and coefficient of elastic uniform shear CT of reinforced
sand, treating it macro-homogeneous.
The experimental investigation includes the determination of physical and
mechanical properties of sand and geogrid reinforcement. The cyclic plate load tests
have been performed on unreinforced and reinforced sand beds at relative densities of
50% and 70%. The sizes of the plates used in the tests are 0.15m square and 0.3m
square and thickness 20 mm each. The sand beds are prepared in rigid steel tanks of
sizes 0.9mx0.9mxl.0m and 1.5mxl.5rnxl.0m for conducting tests on the two plates
respectively. The sand beds are reinforced with 2 to 8 layers of geogrid Netlon
CE-121, having size one to five times the width of the plate. A total of 38 cyclic
plate load tests were conducted for different combinations of the above mentioned
parameters affecting the behaviour.
Considering the cyclic plate load tests as the static tests, the data has been
analyzed to determine the coefficient of elastic uniform compression Cu and damping
capacity ratio. The static strength characteristics like, the bearing capacity ratio
and settlement ratio are also determined. The pressure versus elastic rebound plots
are bilinear; the two straight lines meet at a pressure value close to the ultimate
bearing capacity of the sand bed. The slope of the first line gives Cu, and that of
the other showing post-failure behaviour has been represented by symbol C'u. The
confining pressure and area corrections have been applied to determine the standard
values of Cu and C„ for unreinforced and reinforced sand beds.
A comparison of the damping capacities of the reinforced and the unreinforced
sand beds has been made by measuring the areas of the hysteresis loops of the first
ten cycles of loading and unloading (till the failure of the unreinforced sand bed
ii
occurred) from the pressure-settlement plots.
The second part of the experimental investigation consists of performing
vertical and horizontal block vibration tests (total number 200) on unreinforced and
reinforced sand beds. A rigid steel tank of size 1.5mxl.5mxl.0m was used to prepare
the sand beds reinforced with 2 to 6 geogrid layers of different sizes. An M-20
concrete block of size 0.8mx0.4mx0.4m was cast for performing the block vibration
tests. The frequency and amplitude observations were recorded at four force levels
using the equipment specified in IS:5249-1977 and the soil data logger NE-4201.
The vertical and horizontal vibration test data have been analyzed to determine
the coefficient of elastic uniform compression Cu and the coefficient of elastic
uniform shear CT respectively. The corrections for confining pressure and area of
foundation are applied to obtain the standard values of Cu and CT. The ratio of
dynamic force F to weight of block W, and the strain levels associated with different
tests have been determined. The values of Cu and CT are interpreted at various F/W
ratios and strain levels. In vertical vibration tests, the damping ratio £ has been
determined by the bandwidth method. The damping ratios £, and £2 corresponding to the
first and second modes of vibration in the horizontal vibration tests have also been
determined by the bandwidth method and their values are found to differ, while the
values of CT obtained in both the modes of vibration are almost the same.
Non-dimensional plots and correlations have been obtained for the coefficient of
elastic uniform compression Q, damping capacity ratio, bearing capacity ratio and
the settlement ratio using the cyclic plate load test data. Non-dimensional plots and
correlations have also been developed for the coefficient of elastic uniform
compression Cu, the coefficient of elastic uniform shear CT, damping ratios £ and £i
and the amplitude reduction factors with reference to the number and sizes of geogrid
layers from the vertical and horizontal vibration test data.
An equivalent parameter analysis has been developed to determine the coefficient
of elastic uniform compression and coefficient of elastic uniform shear of reinforced
sand from the coefficient of elastic uniform compression and coefficient of elastic
iii
uniform shear respectively of the unreinforced sand and the elastic modulus of the
geogrid reinforcements. The composite material is assumed to be homogeneous and
elastic with negligible mobilization of interface friction between the soil and
geogrid at low strain levels. The analytically predicted values of coefficient of
elastic uniform compression and coefficient of elastic uniform shear are compared
with the experimental values and a reasonable agreement is obtained.
Based upon the experimental and analytical studies, the following conclusions
are drawn :
(1) In cyclic plate load tests, the values of coefficient of elastic uniform
compression of reinforced sand decrease, with the maximum decrease being 45%.
This decrease is more with the increase in number and decrease in size of
geogrid layers. However, the pressure range for validity of Cu value of
reinforced sand bed is higher than that for the unreinforced sand bed. The
damping capacity is increased, the improvement being more with increase in
number and size of reinforcement layers. The ultimate bearing capacity values
are increased upto about four times and the total settlements are reduced to
less than half as compared to those of unreinforced sand, depending upon the
size and number of geogrid layers.
(2) In vertical vibration tests, the maximum amplitudes are reduced maximum by 43%
for reinforced sand beds. The decrease in amplitudes is generally more with the
increase in size and number of geogrid layers. The resonant frequency is reduced
by a maximum of 14%, the decrease being dependent upon the size and number of
geogrid reinforcements. The damping ratio, £ increases depending upon the size
and number of reinforcements. The coefficient of elastic uniform compression Cu
decreases by a maximum of about 26% depending upon the size and number of the
reinforcement layers. The Cu-values of reinforced sand beds are less than the
Cu-values of unreinforced sand bed for strain levels less than 3%; whereas for
strain levels higher than this, Cu values for reinforced sand beds are more.
This shows that for strain levels less than 3%, the mobilization of interface
IV
friction between sand and geogrid is not significant to contribute to the
coefficient of elastic uniform compression of reinforced sand.
(3) In horizontal vibration tests on reinforced sand beds, the maximum amplitudes
corresponding to both the modes of vibration are reduced upto about 50%
depending upon the size and number of geogrid layers. The resonant frequencies
corresponding to the first and second modes of vibration decrease by a maximum
of 28% and 20%, the decrease being more with the increase in size and number of
reinforcement layers. The damping ratios €>l and £2> f°r tne two modes of
vibration increase depending upon the configuration of the reinforcement and are
found to be different. The coefficient of elastic uniform shear is reduced by a
maximum of 48%, the decrease being dependent upon the size and number of
reinforcement layers. A comparison of the values of coefficient of elastic
uniform compression, (Cul00)10 with the corresponding values of coefficient of
elastic uniform shear, (CT100)10 shows that (Cul00)10/(CT100)10 ratio is 2.8 to
2.95 for unreinforced sand bed whereas it is 3.2 to 3.9 for the reinforced sand
beds. Thus, the decrease in CT is more than the decrease in Cu for the similar
geogrid reinforced sand beds.
The results of this study are especially useful in the design of foundations of
machines, where the natural frequency of the soil-foundation system may lie close to
the operating frequency of machine otherwise and the maximum amplitude exceeds
permissible limits. The maximum amplitudes can be brought under control and the
disturbance during the starting and stopping of the machine can be reduced.
Another important conclusion drawn on the basis of test results is that though
the static strength characteristics of the sand are considerably improved upon
reinforcing with geogrid layers, but the coefficient of elastic uniform compression
is marginally reduced at low strain levels till the mobilization of interface
friction effectively contributes to the modulus of reinforced sand. |
en_US |