DSpace Repository

DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF GUANOSINE AND 8-HYDROXYGUANOSINE

Show simple item record

dc.contributor.author Deepshikha
dc.date.accessioned 2014-11-13T10:21:17Z
dc.date.available 2014-11-13T10:21:17Z
dc.date.issued 1998
dc.identifier M.Tech en_US
dc.identifier.uri http://hdl.handle.net/123456789/8419
dc.guide Goyal, R. N.
dc.description.abstract Purine nucleosides are well known for their metabolic and biological effects on human beings. The development of sophisticated techniques in electrochemistry and growing importance of oxidation reactions in biological systems facilitated determination of two or more compounds simultaneously. The electrochemical studies of biomolecules provide useful and valuable information about their biological redox reactions. Electrochemical oxidation of guanosine and 8-hydroxyguanosine has been carried out at Pyrolytic Graphite Electrode by differential pulse voltammetry in the pH range 2.5-10.3. IF, versus concentration studies at pH 7 suggested that guanosine and 8-hydroxyguanosine can be determined simultaneously using differential pulse voltammetry in the concentration range of 0.1 to 0.0005 mM. en_US
dc.language.iso en en_US
dc.subject CHEMISTRY en_US
dc.subject DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION en_US
dc.subject GUANOSINE en_US
dc.subject 8-HYDROXYGUANOSINE en_US
dc.title DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF GUANOSINE AND 8-HYDROXYGUANOSINE en_US
dc.type M.Tech Dessertation en_US
dc.accession.number 247992 en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record