dc.description.abstract |
The ever increasing urbanisation and industrialisation has led to the increase in demand for
energy supply which has imposed a high pressure on the existing conventional energy
sources. As these resources are available in limited amount in nature, a situation of energy
crisis has occurred. Now, the best possible solution for combating energy crisis is to reduce
the dependence on non-renewable energy sources and tap the potential of renewable energy
resources. Solar energy is one of such renewable resources which can be used for generation
of power either by solar photovoltaic or by solar thermal power plants.
The solar thermal power technology is one of the most promising technologies which
have achieved rapid development in the world. It has been applied on parabolic trough, linear
Fresnel reflector, power tower and parabolic dish. Solar receiver is a photo thermal
conversion component of solar thermal power plants, which absorbs solar radiation and heats
the working fluid. It plays a very crucial role on the efficiency of the entire power plant, so
the design and safety of the receiver is of utmost importance. Among the various designs of
existing receivers, one of the designs is of receiver cavity. The receiver cavity consists of a
large aperture on the front face of the cavity which provides a benefit of large surface area
and low heat loss. Working fluid can attain higher temperature in receiver cavity.
This work presents the design, construction and performance investigation of
solar receiver cavity in form of tubes for a parabolic trough collector. Experimental tests
have been conducted using non-evacuated receiver tube, evacuated receiver tube and
modified receiver cavity. Thermal efficiency has been observed in the range of 44-50%
and 40-50% with the non-evacuated receiver tube and receiver cavity respectively while
with the evacuated receiver tube, the thermal efficiency has been found in the order of
60-70%. Based on the investigations, it has been found that evacuated receiver tube has
better thermal efficiency than the other two configurations of receivers investigated for all
values of performance parameter, (Ti-Ta)/Hb. Further, it has also been observed that modified
receiver cavity has better thermal performance than the non- evacuated receiver tube
compared to the values of performance parameter, (Ti-Ta)/Hb, from 0 to 0.09 K.m2/W.
However, beyond 0.09 K.m2/W, the non- evacuated receiver tube has been found to be more
thermally efficient than the modified receiver cavity. |
en_US |