Reinforced cement concrete (RCC) is one of the most versatile and widely
used construction materials throughout the world, but sometimes, such structures
show distress. One of the main reasons of the distress is corrosion of the
reinforcing steel which mainly depends on quality and quantity of construction
materials, exposed environment, concrete cover thickness etc., besides design and
construction factors, maintenance etc. The assessment of corrosion of reinforcing
steel is rather difficult because the reinforcement is inside the concrete. Thus,
destructive methods, wherever permissible, are generally employed to assess the
corrosion. Apparently, there is still a need to have more experimental data using
simple and non-destructive / partially destructive techniques, which will reflect on
the corrosive state of the reinforcement and the life of the structures. The corrosion
studies of reinforcement in the concrete made with pozzolana cement (fly ash
admixed cement) have led to contradictory results. The work of a number of
workers shows that mixing of fly ash in cement reduces the susceptibility to
corrosion of reinforcement compared to that observed with Ordinary Portland
Cement (OPC) while the work of others shows that susceptibility to corrosion of
reinforcement is enhanced in the presence of fly ash. Similarly, the results of the
effect of fly ash admixed cement on the depth of carbonation, change in pH,
chloride content and permeability of concrete are also contradictory. Further, it has
also been observed that inspite of concrete cover of proper thickness over
reinforcement, there are occasions when the reinforcing steel has got corroded.
Keeping these reports in view, investigations have been carried out to study
the effect of (i) fly ash content in concrete, (ii) use of saline water in preparation of
concrete and (iii) concrete cover thickness on corrosion of reinforcement under
various environments through simple and non-destructive / partially destructive
techniques.
Thus, the corrosion of bare mild steel deformed bars was first investigated
during their exposure to air, potable and saline water upto 1600 hours. Then
cubical and cylindrical specimens with concrete cover thickness of 71 and 26mm
respectively were cast by reinforcing the same mild steel deformed bars in the
centre of the specimens made of three types of concretes; (i) concrete made with
ordinary portland cement (OPC), aggregates and potable water (plain concrete), (ii)
concrete made with OPC, aggregates and saline water (saline concrete), and (iii)
concrete made with fly ash admixed cement (20% replacement of OPC by fly ash),
aggregates and potable water (fly ash admixed concrete). Both the cubical and
cylindrical specimens were then exposed to three environments - (i) air (normal
atmosphere), (ii) potable water (tap water), and (iii) saline water for different time
periods, maximum upto 40 months. During the exposure, it was observed that the
reinforcements in the specimens did not undergo any significant and measurable
corrosion and therefore, only assessment of susceptibility to corrosion of
reinforcement at various intervals of exposure could be made. The assessment
was made by determining the (i) half cell potential, (ii) pH of the concrete.
in
(iii) chloride content, (iv) depth of carbonation, (v) visual inspection and (vi)
gravimetric tests. The results of these investigations have been discussed here and
certain conclusions were drawn.
The mild steel deformed bars, without concrete cover, on exposure to air,
potable and saline water got corroded in the expected order, saline water > potable
water > air. The same MS bars, when used as reinforcements in concrete, did not
get corroded on exposure to the same environments during the exposure period
from 18 months to 40 months. However, monitoring of half cell potential, pH,
carbonation depth and chloride content indicated that the reinforcement, though not
corroded during the period of exposure, has become more or less susceptible to
corrosion depending upon the nature of the concrete, environment and concrete
cover thickness.
The half cell potential studies had indicated that it tends to shift towards more
negative values in presence of moisture and salts while it shifts towards positive
values in the presence of oxygen in dry atmospheric conditions which is in
agreement with earlier reports. Therefore, due attention is to be paid to these
factors while concluding about the state of corrosion on the basis of half cell
potential data. It was also found that fly ash admixed concrete showed less free
chloride content at initial stage of exposure (upto 8-10 months) to saline
environment. However, on later stage of exposure, the free chloride content in fly
ash admixed concrete increases as usual and reaches to more or less same
magnitude as in plain concrete.
IV
Regarding the comparative effect of exposure to various environments, it has
been concluded that susceptibility to corrosion of reinforcement is maximum in
saline water and minimum in air. The specimens made with fly ash admixed
concrete exhibited maximum negative values of half cell potential, maximum
carbonation depth and maximum decrease in pH as compared to plain and saline
concrete indicating that the reinforcement in fly ash admixed concrete has most
favourable conditions for the susceptibility to corrosion.
The values of half cell potential, pH, carbonation depth and chloride content
studies of concrete specimens of different cover thickness exposed to different
environments have led to the conclusion that increase in cover thickness causes
decrease in susceptibility to corrosion of reinforcement.
The visual inspection of reinforcement and gravimetric test indicated no
measurable corrosion of the reinforcement during the period of exposure of
concrete speciments in air (40 months), potable water (18 months) and saline water
(18 months). These observations when combined with half cell potential, pH, depth
of carbonation and chloride content data lead to the definite conclusion that the
simple tests can enable us to know the conditions created in the concrete which
may make the reinforcement more or less susceptible to corrosion. Thus, simple
monitoring like half cell potential, pH, carbonation depth and chloride content may
be useful to assess the possibility of corrosion of reinforcement in RCC structures. |