Please use this identifier to cite or link to this item: http://localhost:8081/xmlui/handle/123456789/8619
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGupta, Rameshwar Nath-
dc.date.accessioned2014-11-15T09:00:25Z-
dc.date.available2014-11-15T09:00:25Z-
dc.date.issued1978-
dc.identifierM.Techen_US
dc.identifier.urihttp://hdl.handle.net/123456789/8619-
dc.guideSwamee, P. K.-
dc.description.abstractPurling is a common feature of sewerage. The location of pumping station is usually decided by engineering judgement. In the present study a rational method for location of pumping station on a main sewer has been evolved which minimises the overall cost of the system. It has been found that pumping constitutes a major portion of sewerage and it is highly sensitive to system parameters.en_US
dc.language.isoenen_US
dc.subjectCIVIL ENGINEERINGen_US
dc.subjectSEWER LINEen_US
dc.subjectPUMPINGen_US
dc.subjectPURLINGen_US
dc.titleOPTIMAL DESIGN OF SEWER LINE INVOLVING PUMPINGen_US
dc.typeM.Tech Dessertationen_US
dc.accession.number175038en_US
Appears in Collections:MASTERS' THESES (Civil Engg)

Files in This Item:
File Description SizeFormat 
CED175038.pdf3.12 MBAdobe PDFView/Open