Title: | OPTIMAL DESIGN OF A CYCLONE SEPARATOR |
Authors: | Singh, Sheo Pratap |
Keywords: | CIVIL ENGINEERING;PARAMETER STUDY;AIR POLLUTION;CYCLONE SEPARATOR |
Issue Date: | 1995 |
Abstract: | In the rapid race of industralization and economic development, the environment which protects human life is being destroyed at a very fast rate. There has been global demand to control air pollution. Among the various pollution control equipment, cyclone separators are constantly used in all those application where only a small portion of the dust to be collected is below 5 microns. In the present study an algorithm for optimal design of a cyclone separator has been developed. The design has been compared with the conventional design. A parameteric study has been conducted to see the effect of discharge, grain size distribution parameters, economic parameters and design efficiency on the optimal cost. |
URI: | http://hdl.handle.net/123456789/6313 |
Other Identifiers: | M.Tech |
Research Supervisor/ Guide: | Bhargava, Renu Swamee, P. K. |
metadata.dc.type: | M.Tech Dessertation |