Please use this identifier to cite or link to this item: http://localhost:8081/xmlui/handle/123456789/5707
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMir, Showkat Ali-
dc.date.accessioned2014-10-10T08:44:33Z-
dc.date.available2014-10-10T08:44:33Z-
dc.date.issued1988-
dc.identifierM.Techen_US
dc.identifier.urihttp://hdl.handle.net/123456789/5707-
dc.guideAhuja, A. K.-
dc.guidePathak, S. K.-
dc.description.abstractA general characteristics of modern building design is to construct light weight structures. This feature produces an increased vulnerability to wind damages. The estimation of any type of load is irnportant for economic design of a structure. Overestimating loads result in uneconomical deSigns and underestimating may result in failures. Hence it is necessary to estimate the loads accurately. Wind load estimation is done by using codes or standards, which are based on wind tunnel tests of isolated structures. However, wind forces get modified by the presence of nearby structures which can produce beneficial shielding or adverse increase in loading. It is, therefore, necessary to identify the situations of adverse loadings so that they can be treated accordingly. The wind interference effects caused due to grouping of structures depend on many parameters, such as distance between structures, their heights, relative positions and wind characteristics etc. Attention has increasingly been given to wind interference effects of structures in last few years and many adverse loading situations have been observed, but the studies made are not enough to form a straight-forward tool for the designers. In the present study the interference effect between two prismatic buildings is studied. The various parameters involved are varied and mean wind pressures, forces and moments on the building are observed. It is seen that mean-force and torsional moment coefficients get increased due to the presence of nearby building in most of the cases.en_US
dc.language.isoenen_US
dc.subjectCIVIL ENGINEERINGen_US
dc.subjectWIND EFFECTen_US
dc.subjectINTERFERENCEen_US
dc.subjectTWO PRISMATIC BUILDINGSen_US
dc.titleWIND INTERFERENCE EFFECTS BETWEEN TWO PRISMATIC BUILDINGSen_US
dc.typeM.Tech Dessertationen_US
dc.accession.number179684en_US
Appears in Collections:MASTERS' THESES (Civil Engg)

Files in This Item:
File Description SizeFormat 
CED 179684.pdf4.42 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.