Please use this identifier to cite or link to this item: http://localhost:8081/jspui/handle/123456789/21778
Full metadata record
DC FieldValueLanguage
dc.contributor.authorRathod, Viral Bipinchandra-
dc.date.accessioned2026-11-25T14:00:31Z-
dc.date.available2026-11-25T14:00:31Z-
dc.date.issued2024-07-
dc.identifier.urihttp://localhost:8081/jspui/handle/123456789/21778-
dc.guideBhalja, Bhavesh R.en_US
dc.description.abstractThe power transformer, which is the most significant and costly component, constitutes around 60% of the total capital investment required for an electrical substation. The presence of partial discharge (PD) within transformer insulation may threaten its integrity and longevity. Partial discharge manifests as localized electrical breakdown that occurs within the insulation material of a transformer, often resulting from imperfections, voids, or contaminants within the insulation structure. Despite being invisible to the naked eye, PD phenomena can induce progressive degradation of insulation integrity, potentially leading to catastrophic failure of the transformer if left undetected/untreated. Therefore, timely identification and pinpointing of PD activity within power transformers are crucial for averting insulation breakdowns. However, the intricate structure of the power transformer presents obstacles in precisely pinpointing the origin of PD activity. In the existing literature, various methods relying on the electrical, electromagnetic, acoustic, optical, and chemical properties of PD signals are widely employed to monitor PD activity in power transformers. Among these methods, the acoustic method offers superior convenience in estimating the three-dimensional PD location. Nevertheless, the acoustic signals experience attenuation as a result of multiple reflections and diffraction from various parts of the power transformer, like copper windings, paper insulation, pressboards, core, and tank, leading to reduced sensitivity. Therefore, the acoustic method may prove ineffective for PD sources deeply embedded in the winding, and the use of costly acoustic sensors further inflates the method’s expenses. In such instances, opting for the electrical method, which involves measurement of the PD signal from the winding terminal, proves to be a more viable option for identifying PD locations within the winding structure.en_US
dc.language.isoenen_US
dc.publisherIIT Roorkeeen_US
dc.titleLOCALIZATION OF PARTIAL DISCHARGE IN POWER TRANSFORMER USING TIME REVERSAL TECHNIQUESen_US
dc.typeThesisen_US
Appears in Collections:DOCTORAL THESES (Electrical Engg)

Files in This Item:
File Description SizeFormat 
19914011_RATHOD VIRAL BIPINCHANDRA.pdf50.24 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.