Please use this identifier to cite or link to this item:
http://localhost:8081/jspui/handle/123456789/18020
Title: | STUDIES ON COINCIDENCE SUMMING CORRECTION IN SCINTILLATION DETECTORS |
Authors: | Mittal, Lovee |
Keywords: | Coincidence Summing Correction;Scintillation Detectors;Detector-Source Separation;Gamma Rays |
Issue Date: | Jun-2014 |
Publisher: | IIT ROORKEE |
Abstract: | Studies on true coincidence summing in scintillation detectors is gaining increasing attention, due to its use in calculating the efficiencies of multi-gamma emitters and obtaining the efficiency calibration curve for these detectors. In the present work, we have carried our extensive measurements on coincidence summing in scintillation detectors using a source Co-60 that emits two gamma rays, namely 1173 and 1332 keV in cascade. The studies were made with Nal(Tl), LaBr3(Ce), LaC13(Ce) and Csl(Tl) detectors for different values of detector-source separation. Coincidence summing correction values were obtained using Vidmar's method. The experimental results were then compared with those obtained from realistic simulations and a good agreement has been found. |
URI: | http://localhost:8081/jspui/handle/123456789/18020 |
metadata.dc.type: | Other |
Appears in Collections: | MASTERS' THESES (Physics) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
G23925.pdf | 6.03 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.