Please use this identifier to cite or link to this item:
http://localhost:8081/jspui/handle/123456789/16982
Title: | PULL OUT ANALYSIS FOR GEOGRIDS IN SAND |
Authors: | Kumar, Amit |
Keywords: | Geogrid Specimens;Granular Soil;Soil-Geogrid;Examines Pull-Out |
Issue Date: | Jun-2014 |
Publisher: | I I T ROORKEE |
Abstract: | This study examines pull-out test results of geogrid specimens embedded in a granular soil. The influence of specimen geometry, normal load and sleeve length on the pull-out force of the geogrid specimen are discussed and the results of laboratory pull-out tests on uniaxial and biaxial geogrid specimen are analyzed. Soil and geogrid properties are fully described and the soil-geogrid interaction behaviour was studied. The conclusions of this study are as follows: I) the influence of - the geogrid specimen width on the pull-out response of the geogrid specimens tested is minimal, ii) the placement of a 0.20 rn long sleeve in the front wall of the pull-out box reduces the magnitude of back calculated soil-geogrid interface shear resistance, iii) pullout resistance of geogrid with different embedded length depends on density of soil; and iv) the coefficient of interaction ranges between 0.5 to I for laboratory tests |
URI: | http://localhost:8081/jspui/handle/123456789/16982 |
metadata.dc.type: | Other |
Appears in Collections: | MASTERS' THESES (Civil Engg) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
G24287.pdf | 5.46 MB | Adobe PDF | View/Open |