Please use this identifier to cite or link to this item: http://localhost:8081/xmlui/handle/123456789/12882
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPatait, Nitin-
dc.date.accessioned2014-12-04T05:32:51Z-
dc.date.available2014-12-04T05:32:51Z-
dc.date.issued2008-
dc.identifierM.Techen_US
dc.identifier.urihttp://hdl.handle.net/123456789/12882-
dc.guidePrasad, J.-
dc.guideSharma, Umesh Kumar-
dc.description.abstractWith the increasing use of self compacting concrete (SCC) in the construction field, it is necessary to study the performance of self compacting concrete in reinforced concrete columns. The purpose of this study is to compare the behavior of self-compacting concrete with same strength of normal vibrated concrete in columns and to study the effect of the various confinement parameters on self-compacting concrete reinforced columns. The parameters of the study were self-compacting concrete vs normal concrete, grade of concrete, longitudinal reinforcement, arrangement of reinforcement, yield strength of transverse reinforcement. The study included measuring load carrying capacity, gain in strength, ductility, stress strain curves and tie strain of confined SCC columns. The experimental programme consisted of casting 48 rectangular short column specimens of size 150mmx 15Omm>700 mm, that included plain and reinforced specimens. Two different configurations of transverse reinforcement were used. In one configuration, 4-120 bars were placed & the other arrangement consisted of 4-10I and 4-8D bars. Transverse reinforcement of 6 mm dia. of mild steel and of high yield strength was used. The pitch of transverse reinforcement was varied from 50 to 150 mm to impart high and low confinements. It was observed 8 bar configuration is more effective. than normal 4 bar configuration. The high yield strength can generate a high degree of confinement and gives, higher percentage' strength gain and ductility. The increase in grade of concrete for SCC, found to impart high/ strength and ductility. Hence, the overall performance of SCC. is much better than NC.en_US
dc.language.isoenen_US
dc.subjectCIVIL ENGINEERINGen_US
dc.subjectSELF COMPACTING CONCRETEen_US
dc.subjectREINFORCED COLUMNSen_US
dc.subjectTRANSVERSE REINFORCEMENTen_US
dc.titlePERFORMANCE OF SELF COMPACTING CONCRETE IN REINFORCED COLUMNSen_US
dc.typeM.Tech Dessertationen_US
dc.accession.numberG13743en_US
Appears in Collections:MASTERS' THESES (Civil Engg)

Files in This Item:
File Description SizeFormat 
G13743.pdf4.76 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.