Please use this identifier to cite or link to this item: http://localhost:8081/xmlui/handle/123456789/12633
Title: EXTRACTIVE DIVIDED WALL DISTILLATION COLUMN: DESIGN AND OPTIMIZATION
Authors: Dnyaneshwar, Gaikwad Aman Kumar
Keywords: CHEMICAL ENGINEERING;EXTRACTIVE DIVIDED WALL DISTILLATION COLUMN;RADFRAC MODEL;ASPEN PLUS SIMULATOR
Issue Date: 2013
Abstract: Distillation is widely used as a separation technique but it consumes more energy. Therefore it’s necessary to find efficient design which will reduce energy consumption maintaining same desired purity. Many attempts have been made in this direction, Petlyuk proposed a promising, thermally integrated design which is highly energy efficient. Further, divided wall column (DWC) was introduced in which fully thermally coupled Petlyuk column configuration was implemented in one single column by providing single vertical wall dividing column into two parts. Out of these two parts, one works as pre or post fractionator, and other as main column. Thermodynamically both Petlyuk column and DWC are equivalent. Divided wall column (DWC) finds many applications in the field of separation of liquid mixture, viz., separation of three or more component mixture, separation of azeotropic mixtures, extractive distillation, reactive distillation, etc. Examples of extractive distillation include separation of aromatic compounds, aqueous alcohol solutions, mixture of hydrocarbons, etc. Amount of energy consumed is the major operating cost factor; therefore optimal design is obtained in terms of minimum energy consumption without compromising with the product quality. Design variables such as reflux ratio operating parameter such as feed temperature extracting agent flow rate and its temperature have significant effect on optimal design. In the present study we designed and optimized extractive dividing wall distillation column for dehydration of bio-ethanol. We used RADFRAC model of ASPEN PLUS simulator and NRTL as property method. In the study we found that for economical and efficient operation proper design of column is important, proper operating parameters like reflux ratio, total number of stages, operating pressure, are important similarly feed condition such as temperature and flow rate also important for economic and efficient operation. By selecting proper feed temperature of mixture to be separated, we can get desired purity with minimum or optimum expenses in terms of reboiler duty and condenser duty. As we have seen with increment in feed temperature recovery of pure ethanol increases but beyond certain value recovery continues to increase but quality decreases continuously along with continuous increase in reboiler duty. Therefore we have to select optimum point at which we recover maximum ethanol with maximum purity.
URI: http://hdl.handle.net/123456789/12633
Other Identifiers: M.Tech
Research Supervisor/ Guide: Kumar, Vineet
metadata.dc.type: M.Tech Dessertation
Appears in Collections:MASTERS' THESES (Chemical Engg)

Files in This Item:
File Description SizeFormat 
Aman.pdf1.31 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.