Please use this identifier to cite or link to this item: http://localhost:8081/xmlui/handle/123456789/12436
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSingh, Shyam Narain-
dc.date.accessioned2014-12-01T06:01:17Z-
dc.date.available2014-12-01T06:01:17Z-
dc.date.issued1982-
dc.identifierM.Techen_US
dc.identifier.urihttp://hdl.handle.net/123456789/12436-
dc.guideSaxena, S. C.-
dc.guideChitore, D. S.-
dc.description.abstractThis dissertation deals with the design and develop-ment of an electronic psychrometer for the measurement of humidity. Thermistors have been used as basic temperature sensing elements. One thermistor has been used as dry bulb thermometer and the other thermister as wet bulb thermometer. TYe changes in the thermistors resistance values have been processed using astable multivibrator circuits. The output of the system has been given to a digital display unit. Existing material on relative humidity measurement has been reviewed in earlier part of the dissertation..en_US
dc.language.isoenen_US
dc.subjectELECTRICAL ENGINEERINGen_US
dc.subjectPSYCHROMETERen_US
dc.subjectINDUSTRIAL USEen_US
dc.subjectPSYCHROMETER INDUSTRIAL USEen_US
dc.titleDEVELOPMENT OF A PSYCHROMETER FOR INDUSTRIAL USEen_US
dc.typeM.Tech Dessertationen_US
dc.accession.number177157en_US
Appears in Collections:MASTERS' THESES (Electrical Engg)

Files in This Item:
File Description SizeFormat 
EED177157.pdf3.1 MBAdobe PDFView/Open