dc.description.abstractThe optimized spot weld has been found to have higher load carrying capacity, strength and fatigue properties than the spot weld prepared at AWS recommended parameter. The load carrying capacity, electrode indentation and hardness of repair spot weld has been found to be higher than the optimized spot weld but the strength of repair spot weld has been found to be lower than that of the optimized spot weld. The columnar structure of weld nugget and grain size in HAZ of repair spot weld has been found to be refined in comparison to those of the optimized spot welden_US
dc.language.isoenen_US
dc.subjectMECHANICAL INDUSTRIAL ENGINEERINGen_US
dc.subjectSTEEL SHEETen_US
dc.subjectRESISTANCE SPOT WELDINGen_US
dc.subjectPREVIOUS WELD JOINTen_US
dc.titleSTUDIES ON REPAIR WELDING OF RESISTANCE SPOT WELD OF STEEL SHEET BY FURTHER USE OF RESISTANCE SPOT WELDING IN THE VICINITY OF PREVIOUS WELD JOINTen_US